MODEL | IES-BATT-14.33 |
Performance | |
Cell technology | LFP (LiFePO4) |
Battery usable energy [1] | 14.33 kWh |
Nominal Voltage | 51.2 V |
Operating Voltage | 44.8 – 56.16 V |
Nominal Output Current | 140 A / 280 A |
BMS protection current | 300 A 1 S |
Parallel | Up to x 3 |
Communication | |
Display | SOC status indicator, LED indicator, LCD display |
Communications | CAN / RS485 / RS232 / Wi-Fi (optional) |
General Specification | |
Dimension (w*d*h) | 800x250x839mm |
Weight | 145 kg |
Installation | Floor stand or Wall mounted |
Operating Temperature [2] | -20 to 60 °C |
Environmental humidity | ≤ 95%RH (no condensation) |
Protection Rating | IP20 |
Cycle Life [3] | 8000 Cycles or ten (10) years @ 80% DOD / 25°C / 0.5C, 70% EOL |
Scalability | Max 15 batteries in parallel |
Application | ON Grid / ON Grid + Backup / OFF Grid |
Compatible PCS | Refer to compatible inverter list |
Standard Compliance | |
Certificates | Cell: UN38.3 / IEC62619 / UL 1642 / JET |
Pack: UN38.3 / IEC62619 / IEC61000 / UKCA (More available upon request) | |
Ordering and Deliverable Part | |
Part | IES-BATT-14.33 |
IES-BATT-14.33 Parallel cable | |
IES-BATT-14.33 to PCS cable |
[1] Test conditions: 100% depth of discharge (DoD), 0.2C rate charge & discharge at 25°C
[2] Charge/discharge derating occurs when the operating temperature from -10°C to 5°C .& 45°C to 55°C
[3] Please refer to the Warranty Letter for applicable conditions, the warranty is due whichever comes first.
KOOL-ENERGY-2kW-24v-ITnerfricaShopIES-BATT-14.33-UserManual-V11-09.20